Instrumentation and Thermocouple Cable>
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
Instrumentation and Thermocouple Cable
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
Instrumentation and Thermocouple Cable
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
-
CABLE, 16 AWG, 1 PAIR, POWER LIMITED TRAY CABLE STRANDED, BARE COPPER PVC FOIL SHIELD PVC JACKET INSTRUMENT TRAY CABLE 105C 300V K1
APPROVED MANUFACTURERS
PART # 323-221-1601
Minimum 250 MeterView All: Instrumentation and Thermocouple Cable
Call for Availability -
Cable, 16 AWG, 1 Pair, stranded tinned copper PVC, PVC overall shield aluminum interlock armored 105C dry, 75C wet 300V color gray CSA #239 FT4 hazardous location
APPROVED MANUFACTURERS
PART # 323-529-1601
Minimum 150 MeterView All: Instrumentation and Thermocouple Cable
Call for Availability -
16 AWG, 1-triad VNTC bare copper cable, PVC/Nylon overall foil shield, PVC jacket, 90C, 600V, conductor coding: black, white, red and numbered
APPROVED MANUFACTURERS
PART # 2AS-1601TOS
Minimum 175 MeterView All: Instrumentation and Thermocouple Cable
Call for Availability -
16 AWG, 1-pair stranded bare copper conductors cable, PVC-Nylon insulation, sun-resistant PVC jacket, tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. 90C, 600V, foil shield with drain wire
APPROVED MANUFACTURERS
PART # 2AS-1601POS
Minimum 150 FeetView All: Instrumentation and Thermocouple Cable
Call for Availability -
Power Limited Tray Cable, 1 Pairs, 16 AWG, 19x29 Strands, 300V, Tinned Copper, PVC Insulation, PCV Jacket
BELDEN
MFR PART # 9410 0602500
PART # 323-011-1601-B
Minimum 100 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
18 AWG, 1-pair VNTC bare copper cable, PVC/Nylon overall foil shield PVC jacket, 90C, 600V, conductor coding: black and white and numbered
APPROVED MANUFACTURERS
PART # 2AS-1801POS
Minimum 250 FeetView All: Instrumentation and Thermocouple Cable
Call for Availability -
Power Limited Tray Cable, 4 Pairs, 18 AWG, 7x26 Strands, 600V, Bare Copper, PVC Jacket
BELDEN
MFR PART # 1064A 0107500
PART # 2AS-1804POS-B
Minimum 150 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
18 AWG, 2-pair stranded bare copper conductors cable, PVC-Nylon insulation, sun-resistant PVC jacket, tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. 90C, 600V, foil shield with drain wire
APPROVED MANUFACTURERS
PART # 2AS-1802POS
Minimum 250 FeetView All: Instrumentation and Thermocouple Cable
Call for Availability -
16 AWG, 2-pair stranded bare copper conductors, PVC-Nylon insulation, sun-resistant PVC jacket, Tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. 90C, 600V, foil shield with drain wire
APPROVED MANUFACTURERS
PART # 2AS-1602SPOS
Minimum 100 MeterView All: Instrumentation and Thermocouple Cable
Call for Availability -
Power Limited Tray Cable, 8 Pairs, 16 AWG, 7x24 Strands, 600V, Bare Copper, PVC Jacket
BELDEN
MFR PART # 1041A 01500
PART # 2AS-1608SPOS-B
Minimum 250 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
Power Limited Tray Cable, 2 Pairs, 18 AWG, 19x30 Strands, 300V, Tinned Copper, PVC Insulation, PVC Jacket
BELDEN
MFR PART # 9552 0601000
PART # 323-035-1802-B
Minimum 150 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
CABLE, 16 AWG, 2 CONDUCTOR, SOLID THERMOCOUPLE TYPE J DUPLEX GLASS BRAID, GLASS BRAID JACKET 482C CONTINUOUS
APPROVED MANUFACTURERS
PART # 328-110-1611J
Available in 150 Feet increments
Minimum 150 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
Power Limited Tray Cable, 1 Pairs, 18 AWG, 19x30 Strands, 300V, Tinned Copper, PVC Insulation, PCV Jacket
BELDEN
MFR PART # 9409 0605000
PART # 323-011-1801-B
Minimum 500 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
16-2P THERMOCOUPLE SOL KX AIA PVC/PVC IO SHD CSA #239 300V 90C FT4 HL
APPROVED MANUFACTURERS
PART # 327-539-1602-KX
Minimum 8 MeterView All: Instrumentation and Thermocouple Cable
In Stock -
Power Limited Tray Cable, 1 Triads, 20 AWG, 19x32 Strands, 300V, Tinned Copper, PVC Insulation, PCV Jacket
BELDEN
MFR PART # 9364 0602500
PART # 323-024-2003-B
Minimum 150 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
Multi-Conductor - Thermocouple Extension Cable 1 FS PR 20 AWG PVC KX Yellow
BELDEN
MFR PART # 3112A 0045000
PART # 327-221-2001-KX-B
Minimum 100 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
Power Limited Tray Cable, 2 Pairs, 18 AWG, 19x30 Strands, 300V, Tinned Copper, PVC Insulation, PCV Jacket
BELDEN
MFR PART # 9368 0601000
PART # 323-036-1802-B
Minimum 250 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
Power Limited Tray Cable, 2 Pair, 22 AWG, 7x30 Strands, 300V, Tinned Copper, PVC Jacket
BELDEN
MFR PART # 9328 0605000
PART # 323-035-2202-B
Available in 250 Feet increments
Minimum 250 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
Power Limited Tray Cable, 2 Pairs, 16 AWG, 7x24 Strands, 300V, Bare Copper, PVC Jacket
BELDEN
MFR PART # 1492A 0107500
PART # 323-231-1602-B
Available in 250 Feet increments
Minimum 250 FeetView All: Instrumentation and Thermocouple Cable
In Stock -
Power Limited Tray Cable, 4 Pairs, 16 AWG, 7x24 Strands, 600V, Bare Copper, PVC Jacket
BELDEN
MFR PART # 1039A 0107500
PART # 2AS-1604SPOS-B
Minimum 250 FeetView All: Instrumentation and Thermocouple Cable
In Stock