
Instrumentation and Thermocouple Cable>
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
Instrumentation and Thermocouple Cable
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
Instrumentation and Thermocouple Cable
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
-
Power Limited Tray Cable, 12 Pairs, 16 AWG, 7x24 Strands, 300V, Bare Copper, PVC Jacket
BELDEN
MFR PART # 31P1612
PART # 323-221-1612-B
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
16-2C THERMOCOUPLE SOL KX PVC DUPLEX NS PVC JKT 105C 300V YEL/RED
APPROVED MANUFACTURERS
PART # 327-200-1602-KX
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
16 AWG, 8-pair stranded bare copper conductors cable, PVC-Nylon insulation, sun-resistant PVC jacket, tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. 90C, 600V, foil shield with drain wire
APPROVED MANUFACTURERS
PART # 2AS-1608POS
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
16 AWG, 4-pair stranded bare copper conductors cable, PVC-Nylon insulation, sun-resistant PVC jacket, tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. 90C, 600V, foil shield with drain wire
APPROVED MANUFACTURERS
PART # 2AS-1604POS
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
18-4P STR BC PVC IND+O/A SHD PVC JKT 105C 300V BLK/WHT#S UL PLTC OR ITC
APPROVED MANUFACTURERS
PART # 323-231-1804
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
CABLE, 18 AWG, 6 PAIR, POWER LIMITED TRAY CABLE STRANDED, BARE COPPER PVC INDIVIDUAL AND OVERALL SHIELD PVC JACKET INSTRUMENT TRAY CABLE 105C 300V K1
APPROVED MANUFACTURERS
PART # 323-231-1806
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
16 AWG, 8-pair stranded bare copper conductors, PVC-Nylon insulation, sun-resistant PVC jacket, Tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. 90C, 600V, foil shield with drain wire
APPROVED MANUFACTURERS
PART # 2AS-1608SPOS
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
16-2T STR TNC PVC/PVC IO SHD AIA 105C DRY / 75C WET 300V GRY CSA#239 FT4 HL
APPROVED MANUFACTURERS
PART # 323-579-1602
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
16-8T STR TNC PVC/PVC IO SHD AIA 105C DRY / 75C WET 300V GRY CSA#239 FT4 HL
APPROVED MANUFACTURERS
PART # 323-579-1608
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Overall Shielded Single and Multipair, 16 AWG, 12 Pair.
LAKE ELECTRONIC CABLE (LLC)
MFR PART # T1612PRS
PART # 323-221-1612
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Overall Shielded Single and Multipair, 16 AWG, 2 Pair.
APPROVED MANUFACTURERS
PART # 323-221-1602
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Overall Shielded Single and Multipair, 16 AWG, 3 Pair.
APPROVED MANUFACTURERS
PART # 323-221-1603
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
CABLE, 16 AWG, 4 PAIR, POWER LIMITED TRAY CABLE STRANDED, BARE COPPER PVC OVERALL FOIL SHIELD PVC JACKET INSTRUMENT TRAY CABLE 105C 300V K1
APPROVED MANUFACTURERS
PART # 323-221-1604
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
CABLE, 16 AWG, 2 CONDUCTOR, SOLID THERMOCOUPLE TYPE J DUPLEX GLASS BRAID, GLASS BRAID JACKET 482C CONTINUOUS
APPROVED MANUFACTURERS
PART # 328-110-1611J
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Cable, 16 AWG, 2 Conductor, thermocouple type K solid duplex glass braid, glass braid temperature 482C continuous
APPROVED MANUFACTURERS
PART # 328-110-1611K
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Overall Shielded Single and Multipair, 16 AWG, 8 Pair.
APPROVED MANUFACTURERS
PART # 323-221-1608
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Overall Shielded Single and Multipair, 16 AWG, 6 Pair.
LAKE ELECTRONIC CABLE (LLC)
MFR PART # T166PRS/22DR
PART # 323-221-1606
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
CABLE, 16 AWG, 16 PAIR, POWER LIMITED TRAY CABLE STRANDED, BARE COPPER PVC OVERALL FOIL SHIELD PVC JACKET INSTRUMENT TRAY CABLE 105C 300V K1
APPROVED MANUFACTURERS
PART # 323-221-1616
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Overall Shielded Single and Multipair, 16 AWG, 24 Pair.
APPROVED MANUFACTURERS
PART # 323-221-1624
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
-
Power Limited Tray Cable, 8 Pairs, 18 AWG, 7x26 Strands, 300V, Bare Copper, PVC Jacket
BELDEN
MFR PART # 1476A 0065000
PART # 323-231-1808-B-6-M
Minimum 1 MeterView All: Instrumentation and Thermocouple Cable