
Instrumentation and Thermocouple Cable>
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
Instrumentation and Thermocouple Cable
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
Instrumentation and Thermocouple Cable
Instrumentation cable is generally used to transmit a low-power signal from a transducer (measuring for example, pressure, temperature, voltage, flow, etc.) to a PLC or DCS process control computer or to a manually operated control panel. It is normally available in 300- or 600-volt constructions with a single overall shield, or with individual shields over each pair (or triad) and an overall shield.
Thermocouple wire is available in either thermocouple grade or extension grade. Extension grade wire is recommended for use in connecting thermocouples to the sensing or control equipment. The conditions of measurement determine the type of thermocouple wire and insulation to be used. Temperature range, environment, insulation requirements, response and service life should be considered. Shop thermocouple wires including Type J, Type K, Type T, Type E, Type N.
-
0.5 MM SQUARED, 5 PAIR, BS5308 PT1 TYPE 1 INDIVIDUALLY AND OVERALL SHIELD COLOR BLUE REDUCED PROPAGATION <15% 16/0.2 MM PAIR COLORS: BLUE AND BLACK
APPROVED MANUFACTURERS
PART # A7-P51-0005LF
Minimum 1 MeterView All: Instrumentation and Thermocouple Cable
Sign In For PricingCall for Availability -
0.5MM/2PR BS5308 PT2 TYPE 2 COLL SCREEN BLUE RP15 16/0.2MM QUAD
APPROVED MANUFACTURERS
PART # A7-S32-0002LF
Minimum 1 MeterView All: Instrumentation and Thermocouple Cable
Sign In For PricingCall for Availability -
16 AWG, 8-pair stranded bare copper conductors cable, PVC-Nylon insulation, sun-resistant PVC jacket, tested per UL requirements for Type TC cables having THWN or THHN (TFFN) conductors. 90C, 600V, foil shield with drain wire
APPROVED MANUFACTURERS
PART # 2AS-1608POS
Minimum 1 FeetView All: Instrumentation and Thermocouple Cable
Sign In For PricingCall for Availability -
0.75MM/2PR PVC/OVERALL SCREEN/PVC/SWA/PVC 300/500V ORANGE BSC TYPE 143 QUAD
APPROVED MANUFACTURERS
PART # A7CT-2402
Minimum 1 MeterView All: Instrumentation and Thermocouple Cable
Sign In For PricingCall for Availability -
0.75 MM SQUARED, 20 PAIR, PVC, OVERALL SHIELD, PVC, STEEL WIRE ARMORED, PVC 300V AC CONDUCTOR TO GROUND, 500V AC BETWEEN CONDUCTORS, COLOR ORANGE BSC TYPE 143
APPROVED MANUFACTURERS
PART # A7CT-2420
Minimum 1 MeterView All: Instrumentation and Thermocouple Cable
Sign In For PricingCall for Availability -
1.27 mm, 1 pair, solid bare copper PE insulation aluminum, laminated moisture barrier color black PE jacket 2.5 mm radial thickness SSI BR1932 6/166065
APPROVED MANUFACTURERS
PART # DATALINK-PE-06
Minimum 1 MeterView All: Instrumentation and Thermocouple Cable
Sign In For PricingCall for Availability