The PSE softstarter is the worlds first compact softstarter with both built-in electronic overload for motor protection and torque control for an excellent control of pumps. The compact design with the most important functionality integrated provides a very efficient starting solution. The illuminated language neutral display and the four button keypad make it easy to take advantage of all the advanced functionality in the softstarter. The display will also provide all the necessary information both during ramping and continuous operation. Build-in electronic overload protection.

Applications

For Motor Protection And Torque Control For An Excellent Control Of Pumps

Spécifications
  • Voltage Rating: 208 - 600 V AC, 24 V DC
  • Amperage Rating: 171 A
  • Wattage: 45 kW At 230 V, 90 kW At 400 V, 110 kW At 500 V
  • Power Supply: 100 - 250 V AC
  • Operating Temperature: -25 To +60 deg C
  • Tightening Torque: Main Circuit: 18 N-m, Supply Circuit: 0.5m, Control Circuit: 0.5 N-m
  • Connecting Capacity: Main Circuit: 8.5 mm Hole Diameter, 17.5 mm Width X 5 mm Thickness, Control And Supply Circuit: (1) 2.5 mm2/(2) 1.5 mm2 Rigid
  • Frequency Rating: 50/60 Hz
  • Terminal Type: Main Circuit: Bars
  • Communication:iled Bus Plug (Optional)
  • Storage Temperature: -40 To +70 deg C
  • Number Of Starts Per Hour: 10 At 3.5 X Ie For 7 sec 50% ON Time 50% OFF Time
  • Starting Capacity At Maximum Rated Current Ie: 684 A For 10 sec
  • Service Factor Percentage: 100%
  • Adjustable Ra Motor Current (ie): 30 - 100%
  • Analog Outputs: 4 - 20 mA
  • Ramp Time: For Start: 1 - 30 sec, Stop: 0 - 30 sec
  • Signal Indication Of Ramp(led): Green
  • Signal Indication Protection (led): Yellow
  • Signal Indication Fault (led): Red
  • Current Limit Function: 5 - 1197 A
Infos techniques et normes

CE Certified, RoHS Compliant

This message only appears when in edit mode.
Please define the message for when services down in the Homepage Site Config property.

Le site rencontre actuellement des difficultés techniques. Nous nous excusons pour la gêne occasionnée et mettons tout en œuvre pour résoudre ce problème rapidement. Veuillez contactez votre représentant local Anixter pour une assistance immédiate.

1.877.Anixter
Description Qté :

Product Label/Description

  • Réf. fabricant
  • Anixter #

Quantité non valide
Envoyer

Impossible d'ajouter des articles supplémentaires