PSE300-600-70 | ABB

ABB | PSE300-600-70 | PSE Open Softstarter, 600 V AC Max, 302A

  • Réf. fabricant PSE300-600-70
  • PART #530934

The PSE softstarter is the worlds first compact softstarter with both built-in electronic overload for motor protection and torque control for an excellent control of pumps. The compact design with the most important functionality integrated provides a very efficient starting solution. The illuminated language neutral display and the four button keypad make it easy to take advantage of all the advanced functionality in the softstarter. The display will also provide all the necessary information both during ramping and continuous operation. Build-in electronic overload protection.


For Motor Protection And Torque Control For An Excellent Control Of Pumps

  • Voltage Rating: 208 - 600 V AC, 24 V DC
  • Amperage Rating: 300 A
  • Wattage: 90 kW At 230 V, 160 kW At 400 V, 200 kW At 500 V
  • Power Supply: 100 - 250 V AC
  • Operating Temperature: -25 To +60 deg C
  • Number Of Starts Per Hour: 10 At 3.5 X Ie For 7 sec 50% ON e 50% OFF Time
  • Communication: Filed Bus Plug (Optional)
  • Terminal Type: Main Circuit: Bars
  • Storage Temperature: -40 To +70 deg C
  • Connecting Capacity: Main Circuit: 10.2 mm Hole Diameter, 20 mm Width X 5 mm Thickness, Control And Supply Circuit: (1) 2.mm2/(2) 1.5 mm2 Rigid
  • Tightening Torque: Main Circuit: 28 N-m, Supply Circuit: 0.5 N-m, Control Circuit: 0.5 N-m
  • Frequency Rating: 50/60 Hz
  • Adjustable Rated Motor Current (ie): 30 - 100%
  • Starting Capacity At Maximum Rated Current Ie: 1200 A For 10 seService Factor Percentage: 100%
  • Signal Indication Of Ramp(led): Green
  • Ramp Time: For Start: 1 - 30 sec, Stop: 0 - 30 sec
  • Signal Indication Fault (led): Red
  • Analog Outputs: 4 - 20 mA
  • Signal Indication Protection (led): Yellow
  • Current Limit Function: - 2100 A
Infos techniques et normes

CE Certified, RoHS Compliant

This message only appears when in edit mode.
Please define the message for when services down in the Homepage Site Config property.

Le site rencontre actuellement des difficultés techniques. Nous nous excusons pour la gêne occasionnée et mettons tout en œuvre pour résoudre ce problème rapidement. Veuillez contactez votre représentant local Anixter pour une assistance immédiate.

Description Qté :

Product Label/Description

  • Réf. fabricant
  • Anixter #

Quantité non valide

Impossible d'ajouter des articles supplémentaires